How we spec and verify closed-cell spray polyurethane foam (ccSPF) in wall and roof assemblies — assembly design, R-value, code barriers, PPE, and equipment-verified quality control. Written for general contractors, builders and inspectors who want documentation they can hand the AHJ. Veteran-owned, BPI-certified.
All-foam everywhere is usually over-spec'd. We optimize the assembly so closed-cell does the air/vapor/structural work and cheaper fill carries the rest of the R.
Our territory (MT/ND/SD/WY) is largely CZ 6–7. Typical targets below — framework only; verify the current adopted code + AHJ.
| Assembly | Typical CZ 6–7 target* | ccSPF note |
|---|---|---|
| Attic / roof | ~R-49 to R-60 | ~R-6.5–7 per inch (aged/LTTR) |
| Above-grade wall | ~R-20+ or R-13 + R-10ci | 2″ ccSPF ≈ R-13 flash layer |
| Air leakage | Blower-door ACH50 per code | ccSPF is the air barrier |
*Illustrative targets, not a code citation. R-value is a rated aged (LTTR) value per the product's ICC-ES report.
SPF chemistry (MDI isocyanate + amine catalyst + blowing agent) is hazardous during spray and cure. Our protocol:
Realized R-value = the product's rated R × install quality. We control the variables that decide in-situ cell structure and adhesion:
Foam does two jobs at once — it stops the air leaks that drive your bills and insulates — and on roofs it even helps hold the deck down in the wind. We spray it to the manufacturer's spec, protect our crew with proper gear, and prove the result with a blower-door test and thickness checks. You get a tighter, more comfortable building and the paperwork to back it up.
You don't have to foam everything. We run a flash-and-fill hybrid: 1.5–2″ of closed-cell against the sheathing for continuous air/vapor control (plus racking stiffness), then fill the rest of the cavity with fiberglass or dense-pack cellulose to hit the assembly R-target — foam-grade air sealing at batt-grade cost on the balance of the R.
In occupied space, foam needs a 15-minute thermal barrier — ½″ gypsum or an approved coating like DC315 (IRC R316.4 / IBC 2603.4). In attics/crawlspaces without regular access, an ignition barrier or approved coating applies (IRC R316.5). Section numbers renumber between editions — confirm the edition your AHJ adopted plus any local amendments.
Yes — we hand over the ICC-ES evaluation report (ESR/ER) for the specific foam so the AHJ has the code basis in hand, along with our installed-thickness and blower-door QA records.
Realized R = rated R × install quality. We run daily 1:1 ratio/AB-draw checks, hold drum/hose/substrate temps to spec (substrate ≥5°F above dew point), verify installed thickness with depth checks/cores, and prove air-sealing with a before/after blower-door ACH50 where the scope calls for it.